Metal Anchors

Fire resistance ETA - 08/0173 
TC 3025-10 
0809-CPR-1078

LOAD CAPACITY   M10 M12 M16
Recommended tension Nsk Non-cracked concrete C20/25 6,3 kN 7,9 kN 16,7 kN
Recommended tension Nsk Cracked concrete C20/25 3,6 kN 4,8 kN 9,5 kN
         
Recommended shearing force Vsk Non-cracked concrete C20/25 8,7 kN 11,0 kN 21,0 kN
Recommended shearing force Vsk Cracked concrete C20/25 8,7 kN 11,0 kN 21,0 kN
         
Recommended flexure Msk In steel  22,9 Nm 34,3 Nm 88,6 Nm

 

INSTALLATION PARAMETERS   M10 M12 M16
Spacing Scr c/c distance 180 mm 210 mm 255 mm
Edge distance Ccr Distance to concrete edge 90 mm 105 mm 128 mm
         

 

 

Artikelnr.Diameterdf (mm)SW (mm)h1 (mm)hnom (mm)hef (mm)tfix (mm)fTinst (Nm)
18891000920205M101217756860104735
18891001020205M101217756860205735
18891001120205M101217756860306735
18891001270205M101217756860508735
18891201030205M12141990817055350
18891201180205M121419908170206850
18891201280205M121419908170307850
18891601230205M1618241109685565120
18891601330205M16182411096852080120
18891601680205M161824110968550110120